Wound Component EST Scanner
|
![]() |
![]() Chroma model 19035 Wound Component EST Scanner |
|
The 19032/19032-P are 5 in 1 Production Safety Analyzer. It can perform AC/DC Hipot, insulation resistance, grounding resistance and dynamic leakage current 5 safety test functions for electronic products. The dynamic leakage current scan device (A190305/A190307) can be connected externally or built in to 19032 Series. It is capable of measuring the complicate safety requirements with easy installation and operation, and is the finest auto safety tester to increase production test efficiency.
Model 19032/19032-P have Twin-PortTM and OSC function to minimize the test time greatly; along with the super large screen display and intelligent operation mode, 19032 is the most powerful single unit for auto safety tester.
FUNCTIONS
- 5KVAC & 6KV DC Hipot Test
- 0.1MΩ~50GΩ /5kV IR Test
- 50mΩ~100kΩ DCR Test
- 8 Channel Scanner
Wound Component Testing Solution
The quality verification test items for Wound Component consist of AC/DC Hipot tests, Insulation Resistance (IR) test and Impulse Winding test. Chroma integrates above tests into 19035 Wound Component EST Scanner series performing safety tests for motor, transformer, heater related wound products. The wound component manufacturers in quality verification testing not only have reliable quality but also control product quality efficiently.
The 19035 Series support 5kVac/6kVdc high voltage output to conform with withstand test requirement for Wound Component, its maximum output current can up to 30mA. Insulation Resistance (IR) test measurement range is 1MΩ to 50G Ω and voltage output can up to 5kV. DCR can measure basic specification for Wound Component and also check the connection before testing safety withstand.
The 19035 Series also include powerful functions in Flashover detection and Open/ Short Check (OSC) as well as programmable voltage, time parameters, etc. for various DUTs features to promote testing reliability and product quality.
Applications
The 19035 is a comprehensive safety tester designed for motor, transformer, heater related wound component requirements. Most of wound components are equipped with multiple winding such as 3-phase motor, dual winding transformer, etc. Moreover, the wound component needs to use Impulse Winding Tester for high voltage winding to check insulation no good of winding device.
The 19035 design is for connecting DWX Series – Impulse Winding Tester directly and using the 19035 8-Channel scanning to reach multiple points completion in one test instead of switching test point by manual. It saves test time and human cost.
The 19035 provides OSC and DCR functions to verify if bad contact or short circuit happened during test procedure. It solves the Wound Components of motor, transformer, etc occurred contact problems, so that test quality greatly enhanced and the life of test device prolonged.
- Motor, Fan : 19035-M / 19035-ML
- Electric Heater Tube : 19035-M / 19035-ML
- Transformer : 19035/ 19035-L
- Switch, Wire : 19035 / 19035L
- Camera Micro Motor, Coil : 19035-S
Model | Description |
---|---|
19035 | Wound Component EST Scanner |
19035-M | Wound Component EST Scanner |
19035-S | Wound Component EST Scanner |
A190345 | High Voltage Cable for Impulse Winding Tester Connection |
A190346 | RS232 Cable for Impulse Winding Tester Connection |
A190347 | GPIB & Handler & Temperature Interface |
A190348 | RS232 Interface |
A190351 | 8ch-16ch HV box for 19035 |
A190358 | Handler Indicator |
A190359 | 16ch HV External Scanning Box (H,L,X) |
A190702 | 40KV HV Test Probe |