Chroma 63700 Series Regenerative DC Electronic Load - Barletta Apparecchi Scientifici

Logo Barletta
Vai ai contenuti
Chiedi
Info
PRODOTTI > Chroma
Regenerative DC Electronic Load Model 63700 Series
logo Chroma
RegenerativeDCElectronicLoad Model63700Series
Regenerative DC Electronic Load Model 63700 Series
Click to view in PDF format (2501KB)
Key Features:

    • Rated power: 6kW, 12kW, 18kW
      • Voltage range: 100V, 600V, 1,200V, 1,800V
        • Current range: Up to 540A
          • High Power Density: 18kW @ 3U height
            • Energy recovery efficiency: Up to 93%
              • Operating modes: Constant Current, Constant Resistance, Constant Voltage, and Constant Power
                • Master/Slave parallel control, up to 10 units in parallel*
                  • User defined current waveform*
                    • 256 sequences directly programmable via the front panel*
                      • Highly accurate voltage and current measurement
                        • Measurement of Protection Points for voltage, current, and Maximum Power Point (Pmax) when DUT's over-current/over-load protection is activated
                          • Time measurement, battery discharge timing*
                            • Intelligent fan control
                              • Protection functions: Over-current (adjustable), over-temperature, over-power (adjustable) protection, over-voltage alarm
                              • Standard USB and LAN interfaces
                              • Optional GPIB or CAN interface

                              *Please call for availability
                                                  Chroma 63700 Series Regenerative DC Electronic Loads are suitable for product reliability testing in various applications, including electric vehicle (EV) battery discharge, fuel cell discharge, high-power power supply aging, DC EV supply equipment (EVSE), unidirectional on-board chargers (OBC), fuel cell systems, energy storage systems (ESS), AC/DC and DC/DC power supply burn-in tests, and various power electronics applications.

                                                  These regenerative DC loads can simulate a wide range of load characteristics while also feeding energy back to the grid, providing an efficient and sustainable solution that reduces test environment temperatures, HVAC power consumption, and power conversion electricity costs.

                                                  The 63700 Series offers high power density within a compact 3U form factor, with power ratings reaching up to 18kW per unit and currents of up to 540A. Users can parallel up to 10 units* for a maximum power of 180kW and a maximum current of 1200A. Voltage options include 100V, 600V, 1200V, and 1800V.

                                                  All models in the series come equipped with external signal control functionality*, allowing for the simulation of real current waveforms. Master/slave control enables parallel operation of identical 63700 units for synchronized dynamic loading. The system can store up to 256 programmable sequences*, which can be loaded at any time, reducing test duration and increasing throughput during automated testing.

                                                  Regarding measurement capabilities, the 63700 Series can perform real-time and precise voltage and current measurements. With the TFT touch display and rotary knob on the front panel, the 63700 Series offers convenient operation and setup. These units can also be controlled via LAN, USB, GPIB, or CAN.

                                                  Additionally, the 63700 Series features overcurrent, over-power, and over-temperature protection functions, as well as an overvoltage alarm mechanism, ensuring product reliability during testing. These attributes make it an ideal test solution for design verification and integration into automated test systems.
                                                  Applications
                                                  Chroma 63700 series of regenerative electronic loads achieve a maximum energy recovery efficiency of up to 93%. Furthermore, they feature high power density, effectively reducing their size and saving space. These loads are well-suited for long-term reliability testing applications across various power sources, including vehicle DC charging stations, unidirectional on-board chargers, automotive battery discharging, fuel cell discharging, and more. By connecting them in parallel, the 63700 series can reach a maximum power of 180kW, making it suitable for power requirements ranging from 5kW to 180kW.
                                                     DC EVSE Stability Testing   
                                                  Single/Bidirectional Onboard Charger Stability Testing
                                                    EV Battery Discharge Testing *   
                                                  AC/DC & DC/DC Converter Life Cycle Testing
                                                  Server & Communication Power Supply Reliability Testing
                                                  Energy Storage System Discharge Testing
                                                      Fuel Cell Discharge Testing    
                                                  Power Electronic Components Inspection or Reliability Testing
                                                      Solar Array Load Testing    
                                                  * Requires external protection fixtures
                                                  Regenerative Loads, Conventional Loads, and Resistive Loads
                                                  The main differences between regenerative loads, conventional loads, and resistive loads lie in the way they dissipate energy, the magnitude of current ripple, the slope of the current waveform, and power density. The key advantage of regenerative loads is their ability to feed consumed energy back to the power grid, reducing energy waste, and helping to decrease carbon emissions. Traditional loads have the advantage of low current ripple and fast current slew rate. Resistors, on the other hand, have the fastest response time but are larger in size, consume more energy, and have the lowest power density. Users can choose the appropriate load based on their specific testing needs. In general, regenerative loads are suitable for endurance testing, reliability testing, stress testing, and battery discharge testing of power supplies, where they can significantly reduce workplace temperatures and electricity expenses.
                                                  Energy Recovery
                                                  The 63700 series features energy recovery DC electronic loads that efficiently convert the consumed electrical energy into AC current and feed it back into the power grid, achieving an impressive efficiency of up to 93%. The reclaimed electrical energy can be utilized by other equipment within the facility, leading to savings in overall energy consumption and reduced carbon emissions, thereby lowering the environmental impact. This approach also effectively reduces the heat generated by the electronic loads during operation, subsequently decreasing air conditioning energy consumption and cutting electricity costs.
                                                  The following two examples illustrate a comparison of the differences between using a conventional electronic load and a regenerative electronic load.
                                                  Example 1

                                                  1,000-hour reliability test with an 11kW On-Board Battery Charger (OBC)
                                                  11kW OBC
                                                  • The conventional electronic load consumes about 11,000kWh during the test.
                                                  • By contrast, the regenerative load consumes about 770kWh, saving as much as 10,230kWh. This translates to about US$ 1,985 worth of energy savings and 3.95 tons of reduced carbon emissions.
                                                  Example 2

                                                  Production of a 30kW EV Charging Station Power Module. During the production process, the average output power of the module is 5kW. Production runs for 20 hours a day, 30 days per month.
                                                  30kW EVSE Power Module
                                                  • When testing with a conventional electronic load, the annual energy consumption is approximately 36.000kWh, resulting in carbon emissions of around 13.932 kg
                                                  • With a regenerative load, the annual energy consumption is approximately 2,520kWh, resulting in carbon emissions of about 975 kg. This leads to a reduction of about 12.96 metric tons of carbon emissions
                                                  • In this example, the annual electrical saving would be US$ 0.194 x 33,480kWh = US$ 6,495 per year not including heat conditioning savings
                                                  Note:

                                                  • The regenerative load (63718-1200-40) has an efficiency of 93%
                                                  • A power consumption of 1kWh equals approximately 0.855 lbs (0.387 kg) of carbon emissions
                                                  • Based on California industrial electricity price at US$0.194/kWh, June 2023
                                                  • These calculations only consider the power consumption of the electronic load and do not take into account other power consumption and costs:
                                                     - 5kW x 20hrs x 30days x 12 months = 36,000kWh;36,000kWh x 0.387kg = 13,932kg
                                                     
                                                    - 0.35kW x 30hrs x 30days x 12months = 2,520kWh;2,520kWh x 0.387kg = 975kg
                                                  High Power Density
                                                  The 63700's exceptional power density enables a rated power of 18kW packaged in a 70% smaller form factor. This revolutionary design challenges the conventional notion of large and cumbersome high-power loads, offering a compact solution that saves valuable laboratory space.
                                                  High Measurement Accuracy and Master-Slave Control
                                                    Chroma 63700 Series regenerative DC loads are equipped with a digital signal microprocessor for optimized speed and control performance. The high measurement accuracy of voltage (0.05%+0.05%F.S.) and current (0.1%+0.1%F.S.) ensures reliable and precise measurements. All models in the series can be operated manually or remotely. For higher-power test applications, users can parallel multiple units in a master-slave setup with synchronous loading to accurately simulate real-world load conditions.
                                                    Basic Mode
                                                      The 63700 series offers constant voltage (CV), constant current (CC), constant resistance (CR), and constant power (CP) modes of operation to meet various test requirements. For example, in the CC and CR modes, when testing the voltage source DUT (Device Under Test), the load can be used to verify whether the DUT's output voltage remains stable under different load conditions. For On Board Charger (OBC), battery chargers or charging stations, when the charger operates in constant current mode, the 63700 uses constant voltage mode to simulate voltage fluctuations in the charging battery, ensuring the accuracy of the charging current at the set output voltage of the charger. When the test object is a battery, the electronic load can be set to constant current or constant power mode for discharging the battery. Many battery testing applications, power consumption, and other conditions can be tested using these two modes of the electronic load.
                                                      Dynamic Mode
                                                        Along with the global energy efficiency and carbon emission reduction trends, the car industry have established technical development standards for new energy vehicles, which define tests for a variety of electric vehicles. The LV123 guidelines specify the vehicle’s electrical characteristics and safety of high-voltage components, whereas the LV148 standard covers tests for electric and electronic components in 48V electrical system motor vehicles. Chroma 62000D has a high-speed CV dynamic response slope that can be controlled up to 180V/ms, which is applicable to the electrical characteristics tests of many vehicle guidelines. When combined with the Chroma Softpanel, the user can even conduct the tests at the push of a button.
                                                        Programmable Load Sequences*
                                                          Chroma 62000D bidirectional DC power supplies have energy recycling function that returns energy to the grid. The internal protection design serves to identify input voltage and frequency anomalies. When detecting any anomalies, the 62000D will automatically turn off the output to ensure safe use of the grid. The 62000D is set up with OVP, OCP, OPP, OTP, Fan Fail, and AC Fault protection circuits. AC Fault protection includes OVP, UVP, Unbalance, Freq. Error, and OCP.

                                                          *This feature is not yet supported, please contact our office for more information
                                                          Battery Discharge Testing*
                                                            Batteries are typically shipped from the factory with a capacity maintained at around 30% to 50%. When the battery capacity exceeds a user-defined percentage during production, it needs to be discharged before shipping.

                                                            The 63700 Series offers users three discharge test modes: constant current (CC)constant resistance (CR) and constant power (CP). By setting the cutoff voltage and stop time (1 second - 100,000 seconds), the load ensures proper termination of the load to prevent over-discharging and potential damage to the battery. In terms of measurement, the device can measure the discharge energy (WH), discharge capacity (AH), and total discharge time of the battery.

                                                            For example, when the Load ON button is pressed to initiate the load, the internal timer of the 63700 starts counting. The timer stops counting only when the battery voltage reaches the set cutoff voltage or when the Load OFF button is pressed to stop the load. The battery discharge test function can also be used to perform discharge time testing for super capacitors and similar applications.

                                                            *This feature is not yet supported, please contact our office for more information
                                                            Sleep Mode
                                                              The 63700 regenerative load provides a sleep mode for optimal efficiency. When the load remains idle for longer than the user-set idle time, the 63700 will shut off the main power source (e.g., module power), retain the system power, and enter sleep mode. In sleep mode, the operating interface will be in a semi-off state, as shown in the image below.
                                                              Intuitive Touchscreen UI
                                                                The device features a convenient 5" color touchscreen that simultaneously displays measurement values and settings. An extra physical control knob and load ON/OFF key allow for precise and quick fine-tuning. This combination of touch and analog control options ensures a seamless and intuitive user experience.
                                                                Constant Current
                                                                List Mode
                                                                Battery Discharge
                                                                System Setup
                                                                Measurement Setting
                                                                Protection
                                                                Safety Mechanisms
                                                                The 63700 features an energy recovery function and has external protection mechanisms. When the 63700 detects AC input over voltage (OV) or under voltage (UV), abnormal frequency (Freq. Error), three-phase imbalance (Unbalance), or over current (OC), it will shut off the module power to ensure safe grid integration. Additionally, the 63700 has internal protection mechanisms such as over voltage alarm (OVA), over current protection (OCP), over power protection (OPP), over temperature protection (OTP), and under voltage protection (UVP). Once any of these internal protection mechanisms are triggered, the 63700 will stop loading.
                                                                Universal AC Power Range 200Vac~480Vac
                                                                The design of the 63700 regenerative load allows for AC power input from anywhere in the world, with an input range of three-phase 200~220Vac and 380~480Vac. Users can purchase the device without having to worry about compatibility with different power configurations in other regions.
                                                                Interface
                                                                The 63700 regenerative load supports various communication interfaces for user control. It comes standard with USB and LAN, and optional GPIB for PC connectivity. Additionally, it features a CAN interface, commonly used in the automotive industry and compliant with CAN2.0 A&B specifications for 11-bit/29-bit frames. This interface allows for high-speed reading of voltage, current, and power parameters with a 10ms response time.
                                                                SoftPanelTM Software Interface
                                                                  In addition to the front panel, the 63700 Series can also be controlled through Chroma's SoftPanel graphical software interface.
                                                                  This user-friendly interface includes an array of functions which help users get started quickly and operate the load conveniently.
                                                                  The 63700 Series features multiple interfaces such as GPIB, USB, and LAN, allowing users to choose the interface that best suits their needs when using a PC to operate the unit.
                                                                  CC Mode
                                                                  System Setup
                                                                  All Settings
                                                                  Report
                                                                  Model
                                                                             Description
                                                                  63700 Series
                                                                    Regenerative DC Electronic Load
                                                                  63718-100-540
                                                                    Regenerative DC Electronic Load 100V/540A/18kW
                                                                  63706-600-40
                                                                    Regenerative DC Electronic Load 600V/40A/6kW
                                                                  63712-600-80
                                                                   Regenerative DC Electronic Load 600V/80A/12kW
                                                                  63718-600-120
                                                                   Regenerative DC Electronic Load 600V/120A/18kW
                                                                  63712-1200-40
                                                                   Regenerative DC Electronic Load 1200V/40A/12kW
                                                                  63718-1200-40
                                                                   Regenerative DC Electronic Load 1200V/40A/18kW
                                                                  63718-1800-40
                                                                   Regenerative DC Electronic Load 1800V/40A/18kW
                                                                  A600009
                                                                   GPIB Cable (200cm)
                                                                  A600010
                                                                   GPIB Cable (60cm)
                                                                  A620039
                                                                   GPIB Interface
                                                                  A620045
                                                                   CAN Interface
                                                                  Divisioni della società




                                                                  ©1999-2020 - Barletta Apparecchi Scientifici Srl
                                                                  Via Prestinari 2 - 20158 Milano Italy  -  p.IVA 09890900153
                                                                  All rights reserved
                                                                  All trademarks are owned by the respective companies